Free shipping from €199 + VAT (mainland Spain and Balearic Islands)WhatsApp +34 670 863 794Reply in < 24 hOur own technical service

AKO Darwin 3-relay wall-mounted controller

AKO Darwin 3-relay wall-mounted controller

Price on request

AKO Darwin 3-relay wall-mounted controller: AKO wall-mounted electronic controller with compressor, defrost and fan relays, 2 or 3 probes and Modbus version.

Request your quote with no obligation.

Questions? Call us on +34 967 219 649 or message us on WhatsApp
We reply to quote requests within 24 hours.

SKU: AKO-D14632 Category:

Description

AKO Darwin 3-relay wall-mounted controller

AKO Darwin three-relay electronic controller in a wall-mounted housing, for small and medium cold rooms and refrigerated cabinets. It manages compressor, defrost and fans, with two NTC probes and two digital inputs or three probes and one digital input, configuration wizard and ECO function.

Main features

  • Compressor (16 A), defrost (8 A) and fan (16 A) relays
  • 2 probes + 2 digital inputs or 3 probes + 1 digital input
  • 2-step initial configuration wizard and ECO function
  • Version with Modbus RS485 communication (AKO-D14632-C)
  • Quick, intuitive menu with hot keys
  • Password protection of parameters
  • High-brightness screen with temperature display and output icons
  • Application presets for quick start-up
  • Easy installation by one person

Applications

  • Small and medium cold rooms for chilled or frozen products
  • Refrigerated cabinets and bottle coolers for bars, cafés and catering
  • Commercial and industrial refrigeration

Versions and references

AKO reference Version
AKO-D14632 230 V~
AKO-D14631 120 V~
AKO-D14632-C 90-240 V~ with Modbus RS485 communication

See the specifications table for technical data.

Downloads

Price on request: add it to your quote request and we will reply with price and lead time.

Technical data sheet · AKO Darwin 3-relay wall-mounted controller

PDF · 12.8 MB · Main data, models and dimensions.

Specifications

Reference

AKO-D14632

Brand

AKO

Range

AKOCONTROL Darwin mural

Relays

COOL 16 A 12(9) A; DEF 8 A 8(4) A; FAN 16 A 12(9) A, 250 V~

Power supply

230 V~, 120 V~ or 90-240 V~ depending on version

Inputs

2 NTC + 2 digital or 3 NTC + 1 digital

Mounting

Wall-mounted, adaptable to flush boxes

Protection rating

IP40

Probes

NTC/PTC (1.5 m NTC probe included)

Measuring range

NTC -50.0 to 99.9 ºC; PTC -50.0 to 150 ºC

Resolution

0.1 ºC (-50 to 100 ºC)

Operating temperature

-10 to 50 ºC, humidity < 90%

Go to Top