The BCP counting scale is the high-resolution version of the range: 60,000 internal divisions and aluminium load cell, with three 6-digit, 20 mm backlit LCD displays for total weight, piece weight and number of pieces. 300 x 230 mm stainless steel pan, ABS housing and IP44 protection.

What it is for

Internal resolution is what decides how far a counting scale can work with light items. By doubling the internal steps compared with a standard model, the BCP distinguishes smaller piece weights and keeps the count reliable when the piece weighs only a few grams.

  • Food industry: counting caps, capsules, labels and packaging components.
  • Warehouse: stocktaking of light items that would be impossible to count by hand.
  • Dispatch: picking orders by units with alerts via the limits function.
  • Bakery and production kitchens: checking small portions and the number of units per tray.
  • Spare parts and fasteners: counting small metal parts with simultaneous reading of weight and quantity.

Technical specifications

Type Bench counting scale, high resolution
Resolution 60,000 internal divisions
Load cell Aluminium
Pan Stainless steel, 300 x 230 mm
Housing ABS
Protection IP44
Display 20 mm backlit LCD displays · three 6-digit displays: total weight, piece weight and number of pieces
Indicators 8 function indicator symbols
Keyboard 20 keys
Mechanical protection Overload protection
Levelling Spirit level and height-adjustable feet
Units kg
Communications Optional RS232, with printer and PC format
Power supply AC/DC adapter 230 Vac 50 Hz
Battery Internal rechargeable
Operating temperature 0 °C to +40 °C

Functions: piece counting, accumulation, totalising, zeroing, tare, net and limits function.

Approval and metrological verification

Internal resolution should not be confused with verification division. The 60,000 internal divisions of the BCP are steps used by the electronics to calculate the piece weight more finely; they are not equivalent to the legal divisions of a verified instrument.

The BCP is intended for internal control of stock and processes, a use for which mandatory periodic verification does not apply. If the scale is used to determine the amount of a sale, the Spanish Metrology Law 32/2014 and Royal Decree 244/2016 require an approved and verified instrument, with periodic verification every two years by an authorised Control Body and re-verification after any repair that affects measurement.

What is supplied

  • BCP counting scale with 300 x 230 mm stainless steel pan, ABS housing and aluminium load cell.
  • Internal rechargeable battery.
  • Spirit level and height-adjustable feet.
  • AC/DC mains adapter 230 Vac 50 Hz.

The RS232 output is optional and is requested when configuring the order.

Bernad® installation and technical service

José Bernad, S.L. has been supplying weighing equipment to the food industry, retail and warehouses from Albacete for almost 40 years. We are a team of 35 people and have our own technical service, without subcontractors, able to calibrate and repair the equipment we sell.

We offer commissioning and programming of the scale as a service: levelling, checking the count with the customer’s actual piece, adjusting the limits function and configuring the RS232 output format if fitted. Ask us when requesting a quote.

Frequently asked questions

What do I gain with 60,000 internal divisions?

Precision when calculating the piece weight. In a counting scale, counting error comes from misjudging what one unit weighs; the finer the internal step, the better that value is captured and the more reliable the quantity shown, especially with pieces weighing just a few grams.

What does the aluminium load cell provide?

It is the usual type of cell in precision bench scales: it offers good response at small and medium capacities and good thermal stability within the unit’s operating range. Together with internal resolution, it is what underpins the reliability of counting light pieces.

How many pieces should be used as a sample?

The more, the better: a larger sample averages out the differences between units and reduces error. As a practical rule, the sample should weigh enough for the scale to resolve it comfortably. If the pieces vary a lot from one another, counting by weight will always have a margin.

Can the result be sent to a computer?

Yes, by adding the optional RS232 output, which sends the data in printer or PC format. It lets you print the count on a ticket or transfer it to a spreadsheet without typing figures by hand, which reduces transcription errors in long stocktakes.

What is the difference between the BCP and the BCD?

Both share high resolution and an aluminium load cell. The BCD adds 100 PLUs with description, weight, units and tare, 16 function symbols and the option of connecting an auxiliary platform for dual-scale operation, as well as including RS232 output as standard.

Where should it be installed?

On a firm, level table, using the spirit level and adjustable feet, and away from draughts and machinery vibrations. In high-resolution equipment those influences are more noticeable than in a conventional scale, because the reading step is finer.

Alternatives and related models

  • BCD counting scale: same high resolution with 100 PLUs, 16 function symbols, RS232 as standard and connection to an auxiliary platform in dual-scale mode.
  • BC counting scale: same format and functions with 30,000 internal divisions, sufficient for pieces with a higher piece weight.
  • BOC counting scale: lets you key in the sample value and offers successive tare, with units in g, kg or lb depending on capacity.
  • DSC counting scale: 24 mm digits for more comfortable reading at continuous counting stations.
  • A70 counting scale: complete production control with more than 9,999 PLUs, user management and reports exportable to Excel.